Enfield Doors is one of the UK’s leading manufacturers of soundproofed acoustic doors. Our acoustic timber doors comply with all building regulations, and we are proud to have received the Quiet Mark accreditation, which is a symbol of quality and excellence reflecting our own company ethos, assuring our customers of the highest standards and the performance of our products.
Acoustic doors with an acoustic performance of 35dB and above are supplied as complete sound attenuating, high performance assemblies with a frame. We can supply dual certifications against fire and most can be supplied in the veneer or laminate of your choice.
Specialist timber internal doors for noise control in commercial building developments and many other locations.
Acoustic Doors Made To Your Specification
- Acoustic door specifications of 35dB and above
- Every door made to order with a range of finishes available
- Fire rated doors supplied with protection from 30 mins to 240 mins
- Glass panels can be added with some limitations
- Bespoke manufacturing options make them suitable for all sectors
- Industry leading accreditations including Quiet Mark
Acoustic Door Finishes
Veneer Facings
Our high quality veneers are matched and assembled by experienced craftsmen for our large stock in a very broad range of timber species
More Information
Glazing Options
Glazed screens can be made in a variety of styles using appropriate glass types and thicknesses to meet the required integrity and insulation.
More InformationAcoustic Door Manufacturing Options
Door Frames
All frames are manufactured in our wood mill from selected timbers keeping us in complete on control regardless of the project size.
More Information
Soundproofing
Our custom made doors can meet all your specifications and ensure soundproofing. Our team can advise on the current technical requirements.
More InformationTechnical Library
Our technical library is a collection of online resources and guides covering our door manufacturing process. This includes detailed PDF downloads and links to partner websites.
If you have any questions please don’t hesitate to contact us.
Acoustic Performance Ratings: 35dB to 45dB+
Suitable For All Sectors
The UK industry standard of measurement is very precise. At an independent test facility the door is subjected to consistent sound waves across the spectrum of frequencies and the average result is then adjusted in a standardised manner because the human ear is not sensitive to every sound. We all know that dogs hear higher pitched noises than humans do.
Each acoustic doorset will have different characteristics at different frequencies so selecting the best solution is not necessarily simply about the high levels. We are here to help and advise you on different doors depending on the level of noise reduction you require so please call us to discuss your particular noise pollution problem.
Thanks to our range of manufacturing options our doorsets are suitable for all business sectors.
- Recording studios
- Theatres
- Schools
- Universities
- Hospitals
- Hotels
- Commercial Offices
dB Comparison Table
| Rating (Rw) | Typical Applications | Acoustic Performance in Practice | Fire Rating Compatibility |
|---|---|---|---|
| 35dB | Hotel bedrooms, general offices, meeting rooms, classrooms | Raised voices next door audible but rarely intelligible | FD30–FD120 |
| 40dB | Confidential meeting rooms, consultation rooms, SEND and music spaces | Normal speech largely inaudible; raised voices muffled | FD30–FD120 |
| 45dB | Premium hotel suites, medical and consultation rooms, music practice rooms | Loud speech largely inaudible | FD30–FD120 |
| 50dB+ | Studios, plant rooms, high-specification commercial | Very high attenuation; near-total speech isolation | FD30–FD120 |
About Our Acoustic Doors
Door Frames
Acoustic doors have seals to stop sound penetrating around the door edge and they will often have an automatic drop seal to seal the gap underneath so most of our sound proof doors are pre-hung in an appropriate frame and they must be fitted as a complete unit. Every door is made to order so size is not a particular issue and there are plenty of options for door and frame finishes.
Walls, Ceilings and Floors
When you have a noise problem you should remember that sound travels through walls, floors, ceilings and structural supports so you will need to give these areas some thought.
Glass Panels
Glass vision panels can be incorporated with some limitations. Fitting a glass panel in an acoustic door has an impact on the performance, so the size and the type of glass matters. This is especially important if the door needs both acoustic and fire certifications.
Fire Resistance
Our acoustic doorsets come with fire rated protection, with a range of doors offering 30 minutes up to 120 minutes of fire resistance.
Sound Levels On Site
A weighted sound reduction value on site (DnT,w) cannot be directly compared with Rw indices because on-site measurements are influenced by factors which are controlled for R2 measurements under laboratory conditions (or do not apply). Factors such as the area controlled for R2 measurements under laboratory conditions (or do not apply). Factors such as the area of separating walls, the volumes and sound absorption properties of source and receiving spaces, installation and various transmission paths through the structure (e.g. ducts, doors, glazing and other openings and service channels) can all affect on site measurements.
As a guide you should factor in a difference of 2 – 3dB for rooms, and as much as 5dB when measured in corridors.
What Our Customers Say
Commercial Acoustic Doorsets: Frequently Asked Questions
What dB rating do I ned for acoustic doors in a hotel, school or office?
It depends on the purpose of the room in question. As a working guide, hotel guest rooms are commonly specified at 30–35dB, general offices and standard meeting rooms at 35dB, and classrooms at 30–35dB, with music or SEND spaces rising to 40dB+.
Confidential meeting rooms, consultation rooms and premium hotel suites usually move to 40–45dB. We manufacture acoustic doorsets from 35dB upwards, so a higher rating comes from the same bespoke build rather than a separate product.
Can acoustic doors also be fire rated?
Yes. As all our doors are custom made, we can manufacture acoustic performance and fire performance into the same doorset. We manufacture bespoke doorsets with acoustic ratings from 35dB and fire resistance from 30 to 120 minutes, so a single order covers both compliance strands and avoids conflicts between ironmongery and seals.
What’s the difference between a 35dB and a 45dB acoustic door
It is a 10dB step, which the ear typically hears as roughly half as loud – but the practical gap is wider than that. At 35dB, raised voices next door are audible but rarely intelligible, which suits general offices, meeting rooms and many hotel bedrooms.
At 45dB, loud speech is largely inaudible, which is why it suits confidential meeting rooms, consultation and medical rooms, music practice spaces and premium suites. We build bespoke doorsets from 35dB upwards, so you can match the rating to the room rather than over specify the project.
Does an acoustic doorset include the frame?
A doorset is the complete tested assembly: door leaf, frame, seals, threshold and ironmongery, supplied together as one system.
That is essential acoustically, because sound leaks at the perimeter. A high performance leaf hung in an untested frame with generous tolerances will not deliver its rated acoustic performance. We manufacture every acoustic doorset to order as a complete unit, so frame, leaf and seals come from one tested build rather than being sourced separately and assembled on site.
What does Quiet Mark accreditation mean on an acoustic door?
Quiet Mark is an independent certification that identifies the quietest products in a category, with products assessed by acoustics specialists and compared against comparable products rather than accepted on the manufacturer’s word. Our acoustic doorsets hold Quiet Mark accreditation.